Lever connectors make a secure, maintenance-free joint between conductors in seconds. Each way has its own grey lever and spring clamp, so you can mix solid, stranded and fine-stranded conductors of different sizes in the same connector. There are no screws to tighten and nothing to come loose when the joint warms and cools.
The transparent window over each clamp shows the stripped conductor, so you and an inspector can see that it is fully inserted. A small test port above each way takes a standard meter probe, which saves opening the joint during fault finding.
Because the spring clamp keeps a constant pressure on the conductor, the joint does not need retightening at periodic inspection. That makes lever connectors a practical replacement for screw terminal strips in many places where joints are hard to reach once the ceiling or panel is closed.
Where to use them
They suit most low-voltage joints inside an enclosure, junction box or luminaire.
- Connecting light fittings to fixed wiring
- Joints in maintenance-free junction boxes
- Joining flexible tails to solid cable
- Extending circuits during refurbishment
- Control panels and small appliances
Choosing the number of ways
Count the conductors that need to meet at the joint and pick a connector with at least that many ways. The 2-way connector joins one conductor to another, for example a fitting tail to a supply core. The 3-way suits a simple loop or a branch. The 5-way gathers several conductors at one point, which is common for neutrals and earths at a ceiling rose or in a junction box.
Put only one conductor in each way. Spare ways can be left empty, so many installers stock the 3-way and 5-way and use them for most joints. Keeping all three sizes in the van means a joint never has to be made with a connector that is too small.
Installation and use
Strip each conductor to 11 mm; the strip gauge is moulded on the side of the housing. Lift the lever fully, push the conductor in until it stops, then press the lever down until it clicks. A gentle pull confirms the clamp has gripped. Fine-stranded conductors go in without ferrules, but a ferrule makes insertion easier if the strands are very fine.
Mount the connectors inside an enclosure that meets the wiring regulations, with cables secured so no strain reaches the joint. To reopen a joint, lift the lever and withdraw the conductor; the connector can be reused.
- Check the conductor size is within the range for the connector
- Never twist conductors together before inserting them
- Isolate the circuit and prove it dead before working on joints
Compliance and packaging
The connectors are tested to EN 60998-2-2 for screwless clamping units and are rated 450 V, 32 A. The housing is self-extinguishing. They come in a resealable tub of 50 that fits in a van stock box, and trade accounts can reorder them in bulk through quick order.