Manufacturer: Voltaris

Twin and earth cable 4.0 mm², 50 m drum

Voltaris flat twin and earth cable with 4.0 mm² copper conductors and a bare earth, supplied on a 50 m drum. Made to BS 6004 for the fixed wiring of lighting, socket and radial circuits in homes, offices and shops, with metre marks on the sheath for quick, accurate cutting.
SKU: VT-TE40-50
In stock
Availability: In stock
Price
$81.50

PRICE BREAKS - The more you buy, the more you save

Quantity Unit price
10–49 $77.42
50–199 $73.35
200+ $69.28

Description

Overview

This is the flat grey PVC cable that runs behind almost every wall and ceiling in a UK building. It has two insulated live conductors, brown for line and blue for neutral, and an uninsulated circuit protective conductor between them. The cable is made to BS 6004 and is the 6242Y type that electricians and inspectors expect to see.

Each drum is wound so the cable pays out flat and without twisting. The sheath is printed every metre with the size, the standard and a running length, so you can see at a glance how much is left and cut exactly what each run needs. The PVC insulation strips cleanly with a standard stripper, and the solid conductors on the smaller sizes go straight into terminals without ferrules.

Where to use it

Twin and earth is for fixed installations inside buildings. It can be clipped to surfaces, run in voids, laid in trunking or buried in plaster when it is in a safe zone or protected as BS 7671 requires.

  • Lighting circuits in houses, flats and offices
  • Ring final and radial socket circuits
  • Immersion heaters, cookers and fixed appliances on the larger sizes
  • Spurs to fused connection units and isolators
  • Refurbishment and rewiring work where existing 6242Y is being extended

Choosing the right size

Size the conductor from the design current, the protective device, the installation method and the voltage drop over the run. As a common starting point, 1.0 mm² and 1.5 mm² suit lighting, 2.5 mm² suits ring and radial socket circuits, and 4.0 mm² and 6.0 mm² suit cookers, larger radials and showers. Insulation, grouping and high ambient temperatures all reduce the current a cable can carry, so always check the derating factors.

The 50 m drum suits a single job or a small repair. The 100 m drum is better value on a rewire and reduces off-cuts. Trade accounts can mix both lengths in one quick order.

Installation and care

Install the cable at or above 0 °C; PVC becomes brittle in the cold and can crack when it is bent. Keep to the minimum bending radius, avoid contact with polystyrene insulation, which draws plasticiser out of the sheath, and sleeve the bare earth in green and yellow at every termination.

Store drums indoors, out of direct sunlight and off the floor. Keep the ends taped so moisture and dust stay out of the conductors.

  • Clip at regular intervals so the cable does not sag
  • Use grommets wherever the cable passes through metal
  • Test insulation resistance and continuity before energising

Compliance and ordering

The cable meets BS 6004 and carries a Construction Products Regulation reaction to fire class of Eca, which is the minimum required for cable installed permanently in buildings. Each drum carries a label with the batch number, size, length and barcode for stock control.

Drums ship singly and can be added to a saved list or reordered from your order history. Larger quantities for projects can be requested through the quote basket.

Demo product: invented for the Cartenvo B2B demo store.

Technical specifications

Specifications

Products specifications

Attribute name Attribute value
Conductor size (mm²) 4.0
Drum length (m) 50
Cores 2 + earth
General
Brand Voltaris
Product type Flat twin and earth cable, type 6242Y
Application Fixed wiring inside buildings
Country of manufacture United Kingdom
Warranty 12 months against manufacturing defects
Performance
Maximum conductor temperature (°C) 70
Operating temperature (°C) -10 to +70 (fixed installation)
Minimum installation temperature (°C) 0
Electrical
Rated voltage (Uo/U, V) 300/500
Circuit protective conductor (mm²) 1.5
Current rating, clipped direct (A) 37
Voltage drop (mV/A/m) 11
Dimensions and weight
Cable dimensions (mm) 5.5 × 10.6
Minimum bending radius 3 × cable width
Net weight (kg) 10.0
Dimensions (L × W × H, mm) 290 × 290 × 110
Materials and construction
Conductor Plain copper, class 2 stranded
Insulation PVC type TI2
Sheath PVC type TM2, grey
Core colours Brown, blue and bare earth
Sheath marking Size, standard, batch and metre marks
Compliance and safety
Standards BS 6004
Reaction to fire (CPR class) Eca
CE / UKCA marked Yes
RoHS compliant Yes
Packaging and ordering
Pack quantity 1 drum
Barcode type EAN-13
Storage temperature (°C) -10 to +40, dry and out of sunlight

FAQs

Which size do I need for a ring final circuit?

A ring final circuit on a 32 A protective device is normally wired in 2.5 mm² twin and earth with a 1.5 mm² earth. Check the installation method and any thermal insulation around the cable, as these can reduce its rating. Your design calculations under BS 7671 always take priority.

Can I bury this cable in the ground or run it outside?

No. Twin and earth has no mechanical protection and its PVC sheath is not designed for sunlight or wet ground. For outdoor and buried runs use steel wire armoured cable instead.

Why is the earth conductor bare?

The circuit protective conductor is left bare inside the sheath to keep the cable flat and compact. At every termination it must be covered with green and yellow sleeving so it is clearly identified.

Is the cable suitable for use in contact with thermal insulation?

It can be installed in or near insulation, but its current rating must be reduced, sometimes by half when it is fully surrounded. Keep it away from expanded polystyrene, which can make the PVC sheath sticky and brittle over time.

Should I buy the 50 m or the 100 m drum?

Choose the 50 m drum for repairs, extensions and single circuits. The 100 m drum suits a full rewire or several circuits and leaves fewer short off-cuts. Both carry the same metre marks, so it is easy to track usage.

How is the cable delivered?

Each drum is labelled and shrink-wrapped, and heavier drums are shipped on a pallet with other heavy items. See the delivery page for options and timings for your area.