FAQs
Which size do I need for a ring final circuit?
A ring final circuit on a 32 A protective device is normally wired in 2.5 mm² twin and earth with a 1.5 mm² earth. Check the installation method and any thermal insulation around the cable, as these can reduce its rating. Your design calculations under BS 7671 always take priority.
Can I bury this cable in the ground or run it outside?
No. Twin and earth has no mechanical protection and its PVC sheath is not designed for sunlight or wet ground. For outdoor and buried runs use steel wire armoured cable instead.
Why is the earth conductor bare?
The circuit protective conductor is left bare inside the sheath to keep the cable flat and compact. At every termination it must be covered with green and yellow sleeving so it is clearly identified.
Is the cable suitable for use in contact with thermal insulation?
It can be installed in or near insulation, but its current rating must be reduced, sometimes by half when it is fully surrounded. Keep it away from expanded polystyrene, which can make the PVC sheath sticky and brittle over time.
Should I buy the 50 m or the 100 m drum?
Choose the 50 m drum for repairs, extensions and single circuits. The 100 m drum suits a full rewire or several circuits and leaves fewer short off-cuts. Both carry the same metre marks, so it is easy to track usage.