Product overview
The Voltcrest 100 kVA standby generator keeps your business running when the mains supply fails. An automatic transfer switch watches the incoming supply. If it fails, the generator starts, comes up to speed and takes over the load within seconds, then hands back to the mains when the supply returns.
The set comes in a weatherproof acoustic enclosure that can stand outside next to the building. We survey the site, supply the transfer switch, install it with your electrician and commission the whole system.
Key features
- Automatic transfer switch
- Weatherproof acoustic enclosure
- Remote monitoring
- Site survey and commissioning included
Where to use it
A standby set is worth having anywhere a power cut costs more than the generator.
- Cool stores and food distribution
- Workshops and production lines with long restart times
- Server rooms and small data centres, alongside a UPS
- Care homes, surgeries and community buildings
- Farms with milking, ventilation or water pumps
Design and construction
A turbocharged, water-cooled diesel engine runs at 1,500 rpm and drives a brushless alternator with automatic voltage regulation. A coolant heater keeps the engine warm while it waits, so it can start and take load straight away even in winter.
The auto mains failure controller runs a programmable exercise cycle each week, logs every event and sends alerts by email or text through the remote monitoring module. The enclosure is galvanised steel with acoustic lining, lockable doors and a bunded base tank.
Sizing and site survey
Our survey looks at your maximum demand, the motors that must restart and which circuits need back-up. In many buildings only part of the load is essential, which can mean a smaller set and lower running costs.
- 50 kVA: a small cool store, workshop or office building
- 100 kVA: larger stores, production lines or several buildings
- UPS systems need generator capacity above their rating
- We can add load banks for testing on request
Maintenance and testing
Standby sets run few hours, so they need care by the calendar as well as by hours. We recommend a service every year or every 250 hours, whichever comes first, with fresh oil, filters and a battery check. Keep the fuel topped up and have it tested yearly for water and bacterial growth.
A full load test once a year shows that the set and the transfer switch will do their job on the day they are needed. Keep the service log with the set and record each test, as insurers and auditors often ask to see it.
Quotes and ordering
Standby systems are priced on request after the site survey. Account customers can request a quote from the product page, track it in their account and add a service plan to the same order. The quote sets out the generator, the transfer switch, cabling, the base and commissioning as separate lines, so your finance team can see exactly what is included. If your company needs approval before ordering, the quote can be sent to the approver from your account.
Demo product: invented for the Cartenvo B2B demo store.