Overview
Steel wire armoured cable is the standard choice when a supply has to leave the building: to a garage, a garden office, a car charger, a pump or a remote distribution board. A layer of galvanised steel wires protects the cores from impact and digging, and can serve as the circuit protective conductor when it is correctly terminated.
This cable has three stranded copper cores in XLPE insulation, bedded and armoured, with a black PVC outer sheath. It is made to BS 5467, the 6943X construction, and is printed with the size and metre marks along its length.
Where to use it
SWA can be buried directly in the ground, clipped to walls, laid on cable tray or pulled through ducts.
- Supplies to outbuildings, garages and garden rooms
- Electric vehicle charge points and gate motors
- External lighting columns and bollards
- Pumps, plant rooms and farm buildings
- Sub-mains to distribution boards on industrial sites
Construction
The XLPE insulation runs at up to 90 °C, which gives a higher current rating than PVC-insulated cable of the same size. The three cores are coloured brown, black and grey. On a single-phase circuit two cores carry line and neutral and the third can be used as an additional earth, which many designers prefer to relying on the armour alone. On a three-phase supply all three cores carry the phases and the armour provides the protective conductor.
The galvanised steel armour is applied over a PVC bedding and protected by a black PVC sheath that resists water, sunlight and most common chemicals. The sheath is printed with the size and a running metre count, so it is easy to measure what has been pulled and what is left on the drum.
Choosing the right size
Long outdoor runs are usually limited by voltage drop rather than current. Work out the design current, then check the drop over the full length: 1.5 mm² suits short lighting runs, 2.5 mm² and 4 mm² suit garden offices and small workshops, and 6 mm² and 10 mm² suit charge points, heavier loads and long runs. Remember the derating for burial depth, ducts and grouping.
Installation and care
Terminate the cable with a compression gland of the correct size and an earth tag so the armour is bonded at the supply end. Shroud each gland to keep moisture out. Bury the cable deep enough to avoid garden tools, lay warning tape above it and record the route.
Do not install below 0 °C, and keep to the minimum bending radius when pulling round corners or into enclosures.
- Use the CW-type gland size given in the specifications
- Seal open drum ends to keep water out of the cores
- Test insulation resistance after installation and before connection
Compliance and ordering
The cable is made to BS 5467 and is CE and UKCA marked. Drums are labelled with batch, size and length. Matching glands, shrouds and cleats can be added to the same order, and trade accounts can buy drums on their agreed terms.